In response to market and consumer concerns about the quality and safety of face masks, STC has invested additional cutting-edge test facilities and actively sought national and international accreditations to provide faster, flexible and professional face mask testing services. We aim at supporting the local and overseas face mask production sectors in producing high-quality masks. STC becomes the first accredited laboratory by both and to offer accredited face mask testing in Hong Kong.
STC provides comprehensive international standard tests such as: Australian AS 4381:2015, Chinese National YY0469-2011, YY/T0969-2013 and GB15979, European Union EN 14683: 2019+AC: 2019 and USA ASTM F2100-19 etc., to meet requirements of face mask export registrations in different countries.
ASTM F2100-19 |
Method |
Level 1 |
Level 2 |
Level 3 |
Bacterial Filtration Efficiency BFE % |
ASTM F2101 |
≥95 |
≥98 |
≥98 |
Particulate Filtration Efficiency PFE % @0.1mm
|
ASTM F2299 |
≥95 |
≥98 |
≥98 |
Differential pressure (Delta P) (mmH₂O/cm²) |
EN 14683 |
<5.0 |
<6.0 |
<6.0 |
Synthetic Blood Penetration (mmHg) |
ASTM F1862 |
80 |
120 |
160 |
Flammability |
16 CFR 1610 |
Class 1 |
Class 1 |
Class 1 |
EN 14683: 2019 |
Method |
Level I |
Level II |
Level IIR |
Bacterial Filtration Efficiency BFE % |
EN 14683 |
≥95 |
≥98 |
≥98 |
Differential pressure (Delta P) (Pa/cm²) |
EN 14683 |
<40 |
<40 |
<60 |
Splash Resistance (kPa) |
EN 14683 |
Not required |
Not Required |
≥16.0 (120 mmHg) |
Microbial Cleanliness (CFU/g) |
EN 14683 |
≤30 |
≤30 |
≤30 |
AS 4381: 2015 |
Method |
Level 1 |
Level 2 |
Level 3 |
Bacterial Filtration Efficiency BFE % |
EN 14683 |
≥95 |
≥98 |
≥98 |
Differential pressure (Delta P) (mmH₂O/cm²) |
EN 14683 |
<4.0 |
<5.0 |
<5.0 |
Synthetic Blood Penetration (mmHg) |
ISO 22609 |
80 |
120 |
160 |
Biocompatibility ISO 10993 |
Method |
Cytotoxicity |
ISO 10993-5 |
Irritation |
ISO 10993-10 |
Skin Sensitization |
ISO 10993-10 |
In addition to the above standards, STC also provides different mask tests to meet the market needs.
• Viral Filtration Efficiency (VFE %)
• GB 15979 Requirements for microbiological indicators
• Antimicrobial efficiency tests
• Antiviral efficiency test
Face Mask Testing Equipment:
STC has invested over $1 million in upgrading its testing equipment to enhance face mask testing capability and deliver faster testing services. STC is fully committed to supporting Hong Kong by providing the local face mask manufacturing sector with the best service in terms of timing and convenience.
BFE | Differential Pressure |
Synthetic Blood Penetration | Flammability |
Application Form |
|
For more information about our Face Mask Test services, please feel free to Contact Us.
OTHER TESTING SERVICES